Map Recent Data Charts Control Radar Alarms Notes Maintenance Contact ☰
Hide battery estimates Generated at 19:49:50 UTC — Refresh
Site Raw Data Adjusted Data Status Last Reading (UTC) Time Since AMP ANGLE AVEL ActuatorTimeout B Batt BoSLBattery CBC CSQ CurrentPercentOpen D DEPTH Depth DepthA DepthA_1V1 EC EmergencyStatus FloatSwitch Flow InvalidResponses InverterBattery ManualEmergencyExit PEAKS RequiredPercentOpen SignalQuality T Temp Turb TurbA Turbw Turbwo U V VEL Velocity W X Y Z
%20Troups_Control_Inlet.csv%20 OFFLINE 2026-09-10 02:10:04 45.8 days - - - - - - - - - - - - - - - - - - - - - - - 100 - - - - - - - - - - - - - - -
Battery estimate — %20Troups_Control_Inlet.csv%20
⚠ No battery column found (expected CBC, BATT, or BATTERY)
Entry_Flow.csv ONLINE 2026-10-25 19:49:42 0 min - - - - - 3839 - - 20 - - - 0.346 - - - - - 0.426905 - - - - - - - - - - - - - - - 0.3589 - - - -
Battery estimate — Entry_Flow.csv
Est. dead date2026-11-15
Est. time remaining✅ 20.6 days
Based on 2000 rows over 6.6 days (col: Batt). Window auto-expanded to 2000 rows (initial 240-row window was too short for a reliable trend). Drop rate: 26.22 mV/day. First point: 4002 mV. Current: 3839 mV. Stop threshold: 3300 mV, slope = -26.22 mV/day.
Entry_Turb_Depth.csv ONLINE 2026-10-25 19:49:35 0 min - - - - - 4158 - - 27 - - - 35.07 - - 32 - - - - - - - - - - 15.06 - - 62.33 0.21 - - - - - - - -
Battery estimate — Entry_Turb_Depth.csv
Est. dead date2028-02-13
Est. time remaining✅ 475.4 days
Based on 2000 rows over 8.6 days (col: Batt). Window auto-expanded to 2000 rows (initial 240-row window was too short for a reliable trend). Drop rate: 1.8 mV/day. First point: 4191 mV. Current: 4158 mV. Stop threshold: 3300 mV, slope = -1.8 mV/day.
HRVP_Turb_Depth.csv ONLINE 2026-10-25 19:49:20 0 min - - - - - 3712 - - 31 - - - 103.81 - - 41 - - - - - - - - - - 16.13 - - 48.04 0.21 - - - - - - - -
Battery estimate — HRVP_Turb_Depth.csv
Est. dead date2026-11-04
Est. time remaining✅ 10.1 days
Based on 2000 rows over 8.6 days (col: Batt). Window auto-expanded to 2000 rows (initial 240-row window was too short for a reliable trend). Drop rate: 40.69 mV/day. First point: 4097 mV. Current: 3712 mV. Stop threshold: 3300 mV, slope = -40.69 mV/day.
Mac_1_Turb_Depth.csv ONLINE 2026-10-25 19:48:34 1 min - - - - - 4162 - - 31 - - - 39.35 - - 37 - - - - - - - - - - 15.33 - - 51.36 0.2 - - - - - - - -
Battery estimate — Mac_1_Turb_Depth.csv
StatusStable ✓
Based on 2000 rows over 8.5 days (col: Batt). Window auto-expanded to 2000 rows (initial 240-row window was too short for a reliable trend).
Mac_3_Flow.csv ONLINE 2026-10-25 19:45:32 4 min - - - - - 4171 - - 31 - - - 0.775 - - - - - 0.163949 - - - - - - - - - - - - - - - 0.051 - - - -
Battery estimate — Mac_3_Flow.csv
Est. dead date2027-07-25
Est. time remaining✅ 272.6 days
Based on 2000 rows over 6.7 days (col: Batt). Window auto-expanded to 2000 rows (initial 240-row window was too short for a reliable trend). Drop rate: 3.19 mV/day. First point: 4171 mV. Current: 4171 mV. Stop threshold: 3300 mV, slope = -3.19 mV/day.
Mac_3_Turb_Depth.csv ONLINE 2026-10-25 19:46:19 3 min - - - - - 4202 - - 31 - - - 74.13 - - 33 - - - - - - - - - - 15.36 - - 59.47 0.21 - - - - - - - -
Battery estimate — Mac_3_Turb_Depth.csv
StatusStable ✓
Based on 2000 rows over 8.6 days (col: Batt). Window auto-expanded to 2000 rows (initial 240-row window was too short for a reliable trend).
OP_4_Turb_Depth.csv ONLINE 2026-10-25 19:48:05 1 min - - - - - 4162 - - 31 - - - 97.3 - - 30 - - - - - - - - - - 15.87 - - 75.52 0.21 - - - - - - - -
Battery estimate — OP_4_Turb_Depth.csv
Est. dead date2029-02-01
Est. time remaining✅ 829.2 days
Based on 2000 rows over 8.8 days (col: Batt). Window auto-expanded to 2000 rows (initial 240-row window was too short for a reliable trend). Drop rate: 1.04 mV/day. First point: 4211 mV. Current: 4162 mV. Stop threshold: 3300 mV, slope = -1.04 mV/day.
OP_5_Radar.csv ONLINE 2026-10-25 19:44:03 5 min 34.08 82.22 195 - - - - 4175 31 - - 614 - - - - - - - - - - 2690C1... - - - - - - - - - - 26 - - - - -
Battery estimate — OP_5_Radar.csv
Est. dead date2030-05-21
Est. time remaining✅ 1304.1 days
Based on 2000 rows over 8.2 days (col: CBC). Window auto-expanded to 2000 rows (initial 240-row window was too short for a reliable trend). Drop rate: 0.67 mV/day. First point: 4200 mV. Current: 4175 mV. Stop threshold: 3300 mV, slope = -0.67 mV/day.
OP_5_Turb_Depth.csv ONLINE 2026-10-25 19:48:34 1 min - - - - - 4187 - - 31 - - - 66.61 - - 27.83 - - - - - - - - - - 15.71 - - 475.2 432.91 - - - - - - - -
Battery estimate — OP_5_Turb_Depth.csv
Est. dead date2028-10-10
Est. time remaining✅ 715.8 days
Based on 2000 rows over 8.8 days (col: Batt). Window auto-expanded to 2000 rows (initial 240-row window was too short for a reliable trend). Drop rate: 1.24 mV/day. First point: 4231 mV. Current: 4187 mV. Stop threshold: 3300 mV, slope = -1.24 mV/day.
Sed_Turb_Depth.csv ONLINE 2026-10-25 19:45:49 4 min - - - - - 4127 - - 31 - - - 45.33 - - 37 - - - - - - - - - - 15.46 - - 58.23 0.21 - - - - - - - -
Battery estimate — Sed_Turb_Depth.csv
Est. dead date2027-06-28
Est. time remaining✅ 245.8 days
Based on 2000 rows over 8.6 days (col: Batt). Window auto-expanded to 2000 rows (initial 240-row window was too short for a reliable trend). Drop rate: 3.36 mV/day. First point: 4187 mV. Current: 4127 mV. Stop threshold: 3300 mV, slope = -3.36 mV/day.
TC_Turb_HarvPond.csv OFFLINE 2026-09-01 03:49:20 54.7 days - - - - - 3267 - - 20 - - - -99.99 - - -99.99 - - - - - - - - - - -99.99 - - 817.67 0.8 - - - - - - - -
Battery estimate — TC_Turb_HarvPond.csv
⚠ Not enough post-replacement data to estimate drop rate
TC_Turb_Mid.csv OFFLINE 2026-09-01 03:53:02 54.7 days - - - - - 3345 - - 21 - - - 0 - - 0 - - - - - - - - - - 0 - - 973.36 14.32 - - - - - - - -
Battery estimate — TC_Turb_Mid.csv
Est. dead date2026-11-01
Est. time remaining⚠️ 6.9 days
Based on 2000 rows over 8.7 days (col: Batt). Window auto-expanded to 2000 rows (initial 240-row window was too short for a reliable trend). Drop rate: 6.49 mV/day. First point: 3608 mV. Current: 3345 mV. Stop threshold: 3300 mV, slope = -6.49 mV/day.
TC_Turb_OutAC.csv OFFLINE 2026-09-03 06:23:36 52.6 days - - - - - 4133 - - 23 - - - 0.84 - - 0 - - - - - - - - - - 17.44 - - 459.45 214.71 - - - - - - - -
Battery estimate — TC_Turb_OutAC.csv
StatusStable ✓
Based on 2 rows over 0 days (col: Batt). ℹ Battery replacement detected (+683 mV jump); estimate uses post-replacement data only.
TC_Turb_SedPond.csv OFFLINE 2026-09-01 03:49:29 54.7 days - - - - 3351 - - - - - 0 - - - - 88.92 - - - - - - - - - 20 - - - - - 514.39 1005.6 - - 0.77 20.9 - -
Battery estimate — TC_Turb_SedPond.csv
⚠ No battery column found (expected CBC, BATT, or BATTERY)
Troops_Senor_Inlet.csv ONLINE 2026-10-25 19:45:36 4 min - - - - 3612 - - - - - - - - - - - - - - - - - - - - T - - - - - 80.07 114 - - 40C131... 1020 127.61 0,1036
Battery estimate — Troops_Senor_Inlet.csv
⚠ No battery column found (expected CBC, BATT, or BATTERY)
Troops_Senor_Mid.csv ONLINE 2026-10-25 19:44:39 5 min - - - - 4176 - - - - - - - - - - - - - - - - - - - - T - - - - - 89.10 31 - - 1B3410... 780 16.22 0,828
Battery estimate — Troops_Senor_Mid.csv
⚠ No battery column found (expected CBC, BATT, or BATTERY)
Troops_Senor_Outlet.csv OFFLINE 2026-08-07 04:57:12 79.7 days - - - - 4009 - - - - - - - - - - - - - - - - - - - - T - - - - - 79.76 296 - - 147008... 1980 5.76 0,327
Battery estimate — Troops_Senor_Outlet.csv
⚠ No battery column found (expected CBC, BATT, or BATTERY)
Troops_Senor_Sed.csv ONLINE 2026-10-25 19:44:37 5 min - - - - 4150 - - - - - - - - - - - - - - - - - - - - T - - - - - 89.16 31 - - 39B3BB... 900 65.69 0,923
Battery estimate — Troops_Senor_Sed.csv
⚠ No battery column found (expected CBC, BATT, or BATTERY)
Troups_Control_Baseflow.csv OFFLINE 2026-05-26 11:59:02 152.4 days - - - 0 - - 2828 - - 0 - - - - - - 2 0 - 0 0 - - - 31 - - - - - - - - - - - - - -
Battery estimate — Troups_Control_Baseflow.csv
⚠ No battery column found (expected CBC, BATT, or BATTERY)
Troups_Control_Inlet.csv ONLINE 2026-10-25 19:48:16 1 min - - - 0 - - 4067 - - 100 - - - - - - 0 0 - 0 13.01 - - - 25 - - - - - - - - - - - - - -
Battery estimate — Troups_Control_Inlet.csv
⚠ No battery column found (expected CBC, BATT, or BATTERY)
Troups_Control_Outlet.csv ONLINE 2026-10-25 19:44:31 5 min - - - 0 - - 3977 - - 0 - - - - - - 0 0 - 0 12.51 - - - 30 - - - - - - - - - - - - - -
Battery estimate — Troups_Control_Outlet.csv
⚠ No battery column found (expected CBC, BATT, or BATTERY)
Troups_Control_Testing.csv OFFLINE 2026-10-23 21:49:16 1.9 days - - - - - - - - - - - - - - - - - - - - - 666 - - - - - - - - - - - - - - - - -
Battery estimate — Troups_Control_Testing.csv
⚠ No battery column found (expected CBC, BATT, or BATTERY)
Troups_GS_Entry.csv ONLINE 2026-10-25 19:46:17 3 min - - - - - - 3922 - - - - - 0 0 0 - - - - - - - - - 17 - - -100 0 - - - - - - - - - -
Battery estimate — Troups_GS_Entry.csv
⚠ No battery column found (expected CBC, BATT, or BATTERY)
Troups_GS_Exit.csv ONLINE 2026-10-25 19:43:37 6 min - - - - - - 3950 - - - - - 1108 234 694.67 - - - - - - - - - 30 - - 0 0 - - - - - - - - - -
Battery estimate — Troups_GS_Exit.csv
⚠ No battery column found (expected CBC, BATT, or BATTERY)
Troups_GS_Inlet.csv ONLINE 2026-10-25 19:45:59 3 min - - - - - - 3920 - - - - - 1095 232.67 714.67 - - - - - - - - - 27 - - 433 661.33 - - - - - - - - - -
Battery estimate — Troups_GS_Inlet.csv
⚠ No battery column found (expected CBC, BATT, or BATTERY)
Troups_GS_Outlet.csv ONLINE 2026-10-25 19:43:22 6 min - - - - - - 3903 - - - - - 685 192 584.33 - - - - - - - - - 31 - - 18 146.33 - - - - - - - - - -
Battery estimate — Troups_GS_Outlet.csv
⚠ No battery column found (expected CBC, BATT, or BATTERY)
Troups_Mac3.csv OFFLINE 2026-09-07 02:27:19 48.8 days - - - - - 4131 - - 20 - - - 0.22 - - 0 - - - - - - - - - - 17.64 - - 131.52 0.24 - - - - - - - -
Battery estimate — Troups_Mac3.csv
Est. dead date2027-12-06
Est. time remaining✅ 406.2 days
Based on 2 rows over 3.9 days (col: Batt). Drop rate: 2.05 mV/day. First point: 4139 mV. Current: 4131 mV. Stop threshold: 3300 mV, slope = -2.05 mV/day.
Troups_Radar_Storage.csv ONLINE 2026-10-25 19:46:09 3 min - - - - 4121 - - - - - - - - - - - - - - - - - - - - T - - - - - 88.25 30 - - 2D62C8... 780 124.23 0,726
Battery estimate — Troups_Radar_Storage.csv
⚠ No battery column found (expected CBC, BATT, or BATTERY)
Troups_R_Inlet_DS.csv ONLINE 2026-10-25 19:46:04 3 min 127.78 85.58 422 - - - - 4118 29 - - 1468 - - - - - - - - - - 5BB2F2... - - - - - - - - - - 33 - - - - -
Battery estimate — Troups_R_Inlet_DS.csv
Est. dead date2027-06-28
Est. time remaining✅ 245.3 days
Based on 2000 rows over 8.8 days (col: CBC). Window auto-expanded to 2000 rows (initial 240-row window was too short for a reliable trend). Drop rate: 3.33 mV/day. First point: 4169 mV. Current: 4118 mV. Stop threshold: 3300 mV, slope = -3.33 mV/day.
Troups_Sed_Outlet.csv OFFLINE 2026-09-07 02:22:58 48.8 days - - - - - 4146 - - 23 - - - -0.05 - - 0 - - - - - - - - - - 17.48 - - 160.59 0.23 - - - - - - - -
Battery estimate — Troups_Sed_Outlet.csv
StatusStable ✓
Based on 3 rows over 3.9 days (col: Batt).

Showing latest readings from 31 sensors in TroupsCreek group. Page generated at 2026-10-25 19:49:50 UTC
Note: The data displayed in the table above is raw sensor data. If you require adjusted/calibrated data, please download the adjusted dataset using the purple download button.


For an analysis of how successful your logs have been, click here: Link
To update your calibration coeffs for each site, click here: Link

No cameras.dat found or no cameras configured.